You have the possibility to switch light with the Troll Comfort. If this mode is activated under menu item 9-8-8, no tube motors can be controlled. Either light/consumer OR tube motors. It is not possible to combine both functions.
Light control with the Troll Comfort - What settings are necessary?
You have the option to switch and control one or more loads up to a total load of 1800 watts (resistive load) via the Troll Comfort. The control options include normal switching times as well as twilight-dependent control. For example, a light can be switched on in the evening when it gets dark and switched off in the morning when it gets light.
The following settings are necessary.
1. Switch on light function under menu item 9-8-8, select ON
2. check light mode (OFF) / device mode (ON) by default the light mode is switched on, that means with the dusk a consumer is switched on, accordingly the light is also switched on with the down key. If you want to switch off a device with the Troll at dusk, change the mode under menu item 9-8-7.
According to the table the commands change.
3. program switching times -light mode Under
menu item 2 you enter the switching times as before.
Note that the UP switching time is used to set the OFF switching time and the DOWN switching time is used to set the ON switching time.
Example: Switching on by dusk, switching off by dawn:
Menu item 2,
Switching time arrow up. Earliest switch-off time 7:00 o'clock, selection Astro switch time
arrow DOWN. Latest switch on time 22:00h, selection Astro
If the light is not to remain switched on all night, a further switch-on and switch-off can be programmed via a second switching time block; to do this, switch on a
second switching time block under menu item 9-5.
The second switching time block can now be set separately under menu item 2.
The up switching time for switching off the lighting can be set, for example, to
23:00 and the down time for switching on the lighting can be set, for example, to 5:00.