Depending on the device, different device settings are available in the configuration.
The device settings can be made via the HomePilot® app and via HomePilot® interface. The images shown here show the HomePilot® App.
Voice control:
The HomePilot® currently supports voice control via Alexa and via Google Assistant. In order for the devices to be found by the providers, the device must be enabled for the service by clicking on the service.
10 Minute Alarm:
When the alarm is turned on, the operator will generate an alarm sound if the gate is open for more than 10 minutes open. The alarm tone sounds every 10 minutes for 30 seconds.
2000 cycles alarm:
If this function is enabled, the operator will signal that the gate needs maintenance by a short alarm tone at certain intervals after 2000 cycles. End Alarm Tone. Turn the power off and back on or press the "P" key for 5 seconds.
Back-Jump Function:
After closing, the back-jump function relieves the load on the drive train by moving briefly (10 mm) in the opposite direction. This is recommended in conjunction with an external emergency release.
Automatic closing:
The drive closes automatically after the selected time has elapsed. If 0 sec is selected, the function is deactivated. Before the door closes automatically, the drive generates an alarm tone for 20 seconds. At the same time, the light flashes.
Drive-up speed:
This function allows you to adjust the speed of the drive-up movement.
The closing speed cannot be changed for safety reasons.
Ventilation position:
You can enter a ventilation position that is approached by DuoFern command when closing.