Activate login via keys on the device:
To activate the login mode, press the clock key and the
SET key.
The clock LED flashes green and the login mode remains active for 120 seconds.
Switch the respective DuoFern transmitter to registration mode. To do this, read the operating instructions for the corresponding DuoFern transmitter.
After successful registration, the control lamp of the RolloTron Standard DuoFern lights up green for 5 seconds.
The control lamp lights up red if the login failed. For example, if
- 20 DuoFern transmitters are already registered
- an attempt is made to register an unsuitable device (e.g. another DuoFern actuator).
Basic note:
Without an end point setting, the RolloTron Standard DuoFern 1400 will only run as long as one of the two control buttons is pressed. Without end point setting, the automatic functions remain blocked.