It is not possible to control Velux products directly via the HomePilot®.
However, it is possible to control them via the Velux Interface KLF 050.
The Velux Interface KLF 050 can control a product or a product group which is equipped with io homecontrol®.
The control of the KLF 050 is done by our Motor actuator potential-free 9471-2.
The tubular motor actuator potential-free 9471-2 connected to the Velux KLF 50 acts like a wired pushbutton/switch.
The running time setting of the Velux window must be observed.
Measure the time that the Velux motor needs for the complete opening and enter this time in the actuator configuration under running time. This way it is also possible to start percent positions.
If you want to use a normal shutter pushbutton for the radio operation, you can connect it to the external inputs of the motor actuator potential-free 9471-2.
Please observe the operating instructions of the
motor actuator potential-free and the Velux Interface KLF 050.