Activate registration via buttons on the device:
Press the clock + SET/Stop button simultaneously for 4 seconds. The clock LED flashes green and the login mode remains active for approx. 120 seconds.
After successful login, the clock LED lights up green for 5 seconds.
Note on runtime setting:
You can move any connected tubular motor to any position, provided that the run time has been set once. The running time is the time required by the tube motor to open the roller shutter completely. This time is used as a reference for calculating all positions. On the Troll Basis DuoFern, you have two options for setting this run time.
Possibility 1:
With the help of a stopwatch, you measure the time When opening of the roller shutter and enter it in the DuoFern control panel.
Possibility 2:
You close the roller shutter completely, then press and hold the Up button and the Clock button simultaneously. After about 4 seconds, the tubular motor starts to open the roller shutter. Keep the keys pressed until the tube motor stops via the limit switch, wait another two seconds and then release the keys. The running time has been measured and saved.