To reset the I-line tubular motor, use the universal setting cable Art. No. 4090-1 or the cord switch setter Art. No. 4090 is required. Please connect this accordingly to the tube motor and then observe the following key combination:
Cord switch setter Art. No. 4090
- Press and hold the button on the tube motor head,
- Press and hold the set button on the cord switch setting unit - Additionally press and hold the up or down button on the cord switch setting unit.
- After approx. 10 seconds, the tube motor acknowledges the reset by pressing briefly in both directions.
If the button on the tube motor head and the setting cable of the tube motor are not accessible, it is also possible to load the factory setting via the cord switch setting device or via a series switch (unlocked).
- Connect the cord switch or the switch so that both directions can be switched to phase at the same time. To do this, connect the up direction of the motor to the setting cable of the cord switch.
- move the motor downwards and after reaching the lower end point keep the down button pressed
- now switch the up direction to phase 6 times every second and leave the up direction on phase at the 6th time by pressing the set button on the cord switch.
- after a few seconds the tubular motor will confirm the reset by pressing briefly, then release the buttons immediately.
-----------------------------------------------------------------------------------
In the following video the reset is described via our universal setting cable Art. No. 4090-1 is described.