Activate login mode via button on the device:
Briefly press the connection button on the tubular motor actuator. The status LED flashes green and the login mode remains active for 120 seconds. After successful login, the STATUS LED lights up constantly green.
Activate login mode via radio code:
In combination with a HomePilot®, the Bridge, the HomeTimer or a DuoFern central operating unit, the tubular motor actuator can be registered with the respective device by entering the radio code. Subsequently, the remote registration function can be used to register other DuoFern devices (for example, DuoFern handheld transmitters).
Important:
After switching on the power supply, the radio code is active for max. 2 hours. After this time has elapsed, activation using the radio code is no longer possible. Then disconnect the Rohrmotor-Akor from the mains for a short time to activate the time window again. The DuoFern radio code can be found on the enclosed label. The radio code can be 6 or 10 digits.
Login mode via remote login function:
If the tubular motor actuator is already registered with the HomePilot®, the Bridge, HomeTimer or the DuoFern central operating unit, you can use the remote registration function.
To do this, call up the tubular motor actuator in the HomePilot® app and select General in the configuration. The remote login function can be started here.
With the HomeTimer type 9498, the function is to be used under the menu item 9-9-8.
In combination with the central operating unit type 9493-1, the function can be found in the device settings.
With the older central operating unit type 9493, use menu item 1-1-2-3.