When setting the end points, the sequence is very important.
Before the end point setting can be started, the gate must be closed. If the gate cannot be closed with the minus key, please press the P key for approx. 5 seconds until the 1 appears in the display, then briefly tap the P key, the 1 flashes, then press the minus key until the gate is closed. Press and hold the P key again until the zero turns. The operator is thus in the correct starting position.
1. Press and hold the P-key for approx. 5 seconds --> the display shows 1
2. Tap the P key the 1 flashes
3. Press and hold the Plus key until the gate is completely open --> the display will show a rotating zero and about half way through the gate will show an L. This will set a reference point. Make sure you release the key immediately when the gate is open, you can also release the key a little earlier and then move to the desired point by tapping briefly.
If there is no L, or the L appears immediately after the start, the microswitch on the motor head must be checked, it may then be bent or defective.
4. Touch the P key and the 1 stops flashing.
5. Tap the Plus key the 2 appears
6. Tap the P key the 2 flashes
7. Press and hold the Minus key until the gate is completely closed a rotating zero will appear in the display and about half way down an L will appear for a few seconds. This will set a reference point. Make sure that you release the key immediately when the gate is closed, you can also release the key a little earlier and then move to the desired point by tapping it briefly.
8. Tap the P key the 2 stops flashing.
9. Tap the Plus key the 3 appears
10. Tap the P key once the gate opens automatically and switches off at the upper end point, the 3 flashes
11. Tap the P key twice the gate closes automatically and switches off at the lower end point, the 3 flashes
12. Tap the P key once the 3 stops flashing
13. Tap the minus key twice the 1 appears
14. Press and hold the P key for approx. 5 seconds the zero rotates
The setting is now complete
You can also find information on end point setting in our video.