For switching times, it is possible to change the destination of the individual devices in the group. By default, devices within a group would receive an UP command for a time from 0:00 to 12:00 and a DOWN command for times between 12:01 and 23:59.
You can adjust these targets manually. To do this, select the appropriate group and open the menu.
Select Automation (OK) > (arrow right) > Time (OK) > select time 1 or 2 > (arrow right) > select all devices the same (OK)
Here you can select if a certain command is sent to all devices of the group or even individually. If you select Individual, you can define for example for roller shutters whether they are controlled with a fixed command like UP, DOWN or an individual position. You can set the percentage value with the up and down button in 5 steps.
In this example, our WZ1 ROLLOTRON moves to 80% at the time of 7:00.